You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
23 lines
811 B
23 lines
811 B
Introduction
|
|
=============
|
|
The power management integrated circuit (PMIC) records the reason the
|
|
Application processor was powered on in Shared Memory.
|
|
The hardware and software used is the shared memory interface. This document
|
|
is not for the purpose of describing this interface, but to identify the
|
|
possible values for this data item.
|
|
|
|
Description
|
|
===========
|
|
Shared memory item (SMEM_POWER_ON_STATUS_INFO) is read to get access to
|
|
this data. The table below identifies the possible values stored.
|
|
|
|
power_on_status values set by the PMIC for power on event:
|
|
----------------------------------------------------------
|
|
0x01 -- keyboard power on
|
|
0x02 -- RTC alarm
|
|
0x04 -- cable power on
|
|
0x08 -- SMPL
|
|
0x10 -- Watch Dog timeout
|
|
0x20 -- USB charger
|
|
0x40 -- Wall charger
|
|
0xFF -- error reading power_on_status value
|
|
|