SPI (Serial Peripheral Interface) busses
|
|
|
|
SPI busses can be described with a node for the SPI controller device
|
|
and a set of child nodes for each SPI slave on the bus. The system's SPI
|
|
controller may be described for use in SPI master mode or in SPI slave mode,
|
|
but not for both at the same time.
|
|
|
|
The SPI controller node requires the following properties:
|
|
- compatible - Name of SPI bus controller following generic names
|
|
recommended practice.
|
|
|
|
In master mode, the SPI controller node requires the following additional
|
|
properties:
|
|
- #address-cells - number of cells required to define a chip select
|
|
address on the SPI bus.
|
|
- #size-cells - should be zero.
|
|
|
|
In slave mode, the SPI controller node requires one additional property:
|
|
- spi-slave - Empty property.
|
|
|
|
No other properties are required in the SPI bus node. It is assumed
|
|
that a driver for an SPI bus device will understand that it is an SPI bus.
|
|
However, the binding does not attempt to define the specific method for
|
|
assigning chip select numbers. Since SPI chip select configuration is
|
|
flexible and non-standardized, it is left out of this binding with the
|
|
assumption that board specific platform code will be used to manage
|
|
chip selects. Individual drivers can define additional properties to
|
|
support describing the chip select layout.
|
|
|
|
Optional properties (master mode only):
|
|
- cs-gpios - gpios chip select.
|
|
- num-cs - total number of chipselects.
|
|
|
|
If cs-gpios is used the number of chip selects will be increased automatically
|
|
with max(cs-gpios > hw cs).
|
|
|
|
So if for example the controller has 2 CS lines, and the cs-gpios
|
|
property looks like this:
|
|
|
|
cs-gpios = <&gpio1 0 0>, <0>, <&gpio1 1 0>, <&gpio1 2 0>;
|
|
|
|
Then it should be configured so that num_chipselect = 4 with the
|
|
following mapping:
|
|
|
|
cs0 : &gpio1 0 0
|
|
cs1 : native
|
|
cs2 : &gpio1 1 0
|
|
cs3 : &gpio1 2 0
|
|
|
|
|
|
SPI slave nodes must be children of the SPI controller node.
|
|
|
|
In master mode, one or more slave nodes (up to the number of chip selects) can
|
|
be present. Required properties are:
|
|
- compatible - Name of SPI device following generic names recommended
|
|
practice.
|
|
- reg - Chip select address of device.
|
|
- spi-max-frequency - Maximum SPI clocking speed of device in Hz.
|
|
|
|
In slave mode, the (single) slave node is optional.
|
|
If present, it must be called "slave". Required properties are:
|
|
- compatible - Name of SPI device following generic names recommended
|
|
practice.
|
|
|
|
All slave nodes can contain the following optional properties:
|
|
- spi-cpol - Empty property indicating device requires inverse clock
|
|
polarity (CPOL) mode.
|
|
- spi-cpha - Empty property indicating device requires shifted clock
|
|
phase (CPHA) mode.
|
|
- spi-cs-high - Empty property indicating device requires chip select
|
|
active high.
|
|
- spi-3wire - Empty property indicating device requires 3-wire mode.
|
|
- spi-lsb-first - Empty property indicating device requires LSB first mode.
|
|
- spi-tx-bus-width - The bus width (number of data wires) that is used for MOSI.
|
|
Defaults to 1 if not present.
|
|
- spi-rx-bus-width - The bus width (number of data wires) that is used for MISO.
|
|
Defaults to 1 if not present.
|
|
- spi-rx-delay-us - Microsecond delay after a read transfer.
|
|
- spi-tx-delay-us - Microsecond delay after a write transfer.
|
|
|
|
Some SPI controllers and devices support Dual and Quad SPI transfer mode.
|
|
It allows data in the SPI system to be transferred using 2 wires (DUAL) or 4
|
|
wires (QUAD).
|
|
Now the value that spi-tx-bus-width and spi-rx-bus-width can receive is
|
|
only 1 (SINGLE), 2 (DUAL) and 4 (QUAD).
|
|
Dual/Quad mode is not allowed when 3-wire mode is used.
|
|
|
|
If a gpio chipselect is used for the SPI slave the gpio number will be passed
|
|
via the SPI master node cs-gpios property.
|
|
|
|
SPI example for an MPC5200 SPI bus:
|
|
spi@f00 {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
compatible = "fsl,mpc5200b-spi","fsl,mpc5200-spi";
|
|
reg = <0xf00 0x20>;
|
|
interrupts = <2 13 0 2 14 0>;
|
|
interrupt-parent = <&mpc5200_pic>;
|
|
|
|
ethernet-switch@0 {
|
|
compatible = "micrel,ks8995m";
|
|
spi-max-frequency = <1000000>;
|
|
reg = <0>;
|
|
};
|
|
|
|
codec@1 {
|
|
compatible = "ti,tlv320aic26";
|
|
spi-max-frequency = <100000>;
|
|
reg = <1>;
|
|
};
|
|
};
|
|
|