* Kryo EDAC node Kryo EDAC node is defined to describe on-chip error detection and correction for the Kryo core. Kryo will report all SBE and DBE found in L1/L2/L3/SCU caches in two registers: ERRXSTATUS - Error Record Primary Status Register ERRXMISC0 - Error Record Miscellaneous Register Current implementation of Kryo ECC mechanism is based on interrupts. The following section describes the DT node binding for kryo_cpu_erp. Required properties: - compatible : Shall be "arm,arm64-kryo-cpu-erp". - interrupts : Interrupt-specifier for L1/L2, L3/SCU error IRQ(s) - interrupt-names : Descriptive names of the interrupts Example: kryo-erp { compatible = "arm,arm64-kryo-cpu-erp"; interrupts = <1 6 4>, <1 7 4>, <0 34 4>, <0 35 4>; interrupt-names = "l1-l2-faultirq", "l1-l2-errirq", "l3-scu-errirq", "l3-scu-faultirq"; };