@ -0,0 +1,100 @@ |
||||
|
||||
HPSA - Hewlett Packard Smart Array driver |
||||
----------------------------------------- |
||||
|
||||
This file describes the hpsa SCSI driver for HP Smart Array controllers. |
||||
The hpsa driver is intended to supplant the cciss driver for newer |
||||
Smart Array controllers. The hpsa driver is a SCSI driver, while the |
||||
cciss driver is a "block" driver. Actually cciss is both a block |
||||
driver (for logical drives) AND a SCSI driver (for tape drives). This |
||||
"split-brained" design of the cciss driver is a source of excess |
||||
complexity and eliminating that complexity is one of the reasons |
||||
for hpsa to exist. |
||||
|
||||
Supported devices: |
||||
------------------ |
||||
|
||||
Smart Array P212 |
||||
Smart Array P410 |
||||
Smart Array P410i |
||||
Smart Array P411 |
||||
Smart Array P812 |
||||
Smart Array P712m |
||||
Smart Array P711m |
||||
StorageWorks P1210m |
||||
|
||||
Additionally, older Smart Arrays may work with the hpsa driver if the kernel |
||||
boot parameter "hpsa_allow_any=1" is specified, however these are not tested |
||||
nor supported by HP with this driver. For older Smart Arrays, the cciss |
||||
driver should still be used. |
||||
|
||||
HPSA specific entries in /sys |
||||
----------------------------- |
||||
|
||||
In addition to the generic SCSI attributes available in /sys, hpsa supports |
||||
the following attributes: |
||||
|
||||
HPSA specific host attributes: |
||||
------------------------------ |
||||
|
||||
/sys/class/scsi_host/host*/rescan |
||||
|
||||
the host "rescan" attribute is a write only attribute. Writing to this |
||||
attribute will cause the driver to scan for new, changed, or removed devices |
||||
(e.g. hot-plugged tape drives, or newly configured or deleted logical drives, |
||||
etc.) and notify the SCSI midlayer of any changes detected. Normally this is |
||||
triggered automatically by HP's Array Configuration Utility (either the GUI or |
||||
command line variety) so for logical drive changes, the user should not |
||||
normally have to use this. It may be useful when hot plugging devices like |
||||
tape drives, or entire storage boxes containing pre-configured logical drives. |
||||
|
||||
HPSA specific disk attributes: |
||||
------------------------------ |
||||
|
||||
/sys/class/scsi_disk/c:b:t:l/device/unique_id |
||||
/sys/class/scsi_disk/c:b:t:l/device/raid_level |
||||
/sys/class/scsi_disk/c:b:t:l/device/lunid |
||||
|
||||
(where c:b:t:l are the controller, bus, target and lun of the device) |
||||
|
||||
For example: |
||||
|
||||
root@host:/sys/class/scsi_disk/4:0:0:0/device# cat unique_id |
||||
600508B1001044395355323037570F77 |
||||
root@host:/sys/class/scsi_disk/4:0:0:0/device# cat lunid |
||||
0x0000004000000000 |
||||
root@host:/sys/class/scsi_disk/4:0:0:0/device# cat raid_level |
||||
RAID 0 |
||||
|
||||
HPSA specific ioctls: |
||||
--------------------- |
||||
|
||||
For compatibility with applications written for the cciss driver, many, but |
||||
not all of the ioctls supported by the cciss driver are also supported by the |
||||
hpsa driver. The data structures used by these are described in |
||||
include/linux/cciss_ioctl.h |
||||
|
||||
CCISS_DEREGDISK |
||||
CCISS_REGNEWDISK |
||||
CCISS_REGNEWD |
||||
|
||||
The above three ioctls all do exactly the same thing, which is to cause the driver |
||||
to rescan for new devices. This does exactly the same thing as writing to the |
||||
hpsa specific host "rescan" attribute. |
||||
|
||||
CCISS_GETPCIINFO |
||||
|
||||
Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). |
||||
|
||||
CCISS_GETDRIVVER |
||||
|
||||
Returns driver version in three bytes encoded as: |
||||
(major_version << 16) | (minor_version << 8) | (subminor_version) |
||||
|
||||
CCISS_PASSTHRU |
||||
CCISS_BIG_PASSTHRU |
||||
|
||||
Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. |
||||
These are used extensively by the HP Array Configuration Utility, SNMP storage |
||||
agents, etc. See cciss_vol_status at http://cciss.sf.net for some examples. |
||||
|